View the overview on the Device page, or open Hardware Identification from the Checks tab. Browse processor, memory, storage, display, camera and battery categories. Available fields distinguish current system readings, model specifications and imported log observations, with source explanations. A model specification is catalog information, not proof of the actual component model, manufacturer or repair history of a particular device.
The current Checks entry identifies hardware information. It does not provide the former six manual hardware-condition tests. Existing old-format records are retained for historical viewing; new hardware reports do not include those former test results. A missing field does not establish a fault, a zero value or certification.
02How do battery files and configuration logs differ?
The battery guide uses supported existing Analytics, log-aggregated and related files. The configuration guide explains obtaining supported diagnostic files such as sysdiagnose. The app reads only implemented supported fields; it does not guarantee support for every file with the same name, device or OS version.
Battery files may be available in Settings → Privacy & Security → Analytics & Improvements → Analytics Data. The system controls whether and when files are generated. Changing a setting does not create the required log immediately, and no fixed waiting time guarantees one. Follow Apple's instructions for collecting a configuration log on your device; see Apple Profiles and Logs. The app does not generate system logs or read the entire Analytics Data list directly.
Save a file to Files if needed, select it in the app, review the selection and original-copy option, and explicitly confirm parsing. Available local hardware information and current-device reports remain usable without a log.
03How do I receive a file through system sharing?
Select one diagnostic file in Files or another app supporting file sharing, open the share sheet and choose 电池健康分析. Tap Receive File to copy and verify it locally. Once staged, tap Done to close sharing, then open the main app yourself.
Use View and Confirm under Shared Staged Files before parsing, or discard a pending item. The extension does not open the main app, parse or generate a report automatically. This entry accepts files, rather than standalone web links, plain text, images, audio, video or multiple selected files. The single-file limit and total staged-queue limit are 512 MiB, with at most three queued items. Successful receipt does not guarantee that the contents can be parsed.
04How should I interpret battery readings?
Current charge and a logged health percentage are different data. A raw health field in a log is not the current reading from system Settings. The app does not derive health from capacity values whose units have not been verified. A log may be old or belong to another device; check each field's source, observation time and device group. Import time does not replace an unavailable field observation time.
Confirm device and battery-segment grouping before comparing records. Battery replacement, incompatible sources or different rules should not be forced into one trend. A line between records connects existing observations; it does not represent continuous sampling. The app does not predict battery lifespan, certify original components or provide official service findings.
05How do I save and share reports?
Generate a report from Hardware Identification, or use an imported log to create a log report. Logs are not associated with the current device by default. Current-device information is included only after your explicit same-device attestation; the app does not verify that association automatically.
Review the actual image or PDF before sharing. Model identifiers and report IDs are hidden by default. Exports exclude filenames, private paths, file hashes, field source paths and original logs. Clearing app records cannot recall a copy already held by a recipient.
06How do the floating monitor and widgets work?
The floating monitor uses system Picture in Picture and is experimental. Select at most two available metrics. Aggregate system CPU, supported network-interface rates, this app's physical memory footprint, display refresh timing, system thermal state and current charge have separate scopes and limits. Thermal state is not temperature in degrees; interface rates are not traffic attributed to another app; this app's memory is not whole-system used memory. System support, lifecycle or background restrictions can pause updates. Check the actual sampling time.
Add Home Screen widgets manually through the system gallery. The app updates a shared summary and requests a system refresh, without guaranteeing an immediate change on the Home Screen. Log health and device charge retain separate sources and observation times. Widgets show the last shared snapshot and availability or stale states, without a real-time guarantee.
07File retention, deletion and privacy choices
Long-term retention of original files is off by default. A retained copy is added only when you explicitly choose it. Local temporary copies can still exist during receipt, confirmation and parsing. Deleting a retained original preserves parsed records and saved reports. Refer to the app's confirmation and actual results for the scope of clearing local records; originals outside the app remain untouched. Retry any reported failure.
Manage optional analytics in Settings → Privacy and Usage Analytics. It is initially off, and Firebase Analytics initializes after explicit opt-in. Declining or disabling it does not affect core local features. Advertising privacy is managed separately. Where required, the app provides an advertising privacy form or Manage Advertising Privacy Choices. System tracking permission can be changed in system Settings. Denying tracking or turning analytics off does not imply that all data collection stops. See the Privacy Policy.
08Contact support
Email d20258002@163.com with the app version, device and OS version, file type, steps and an error description with sensitive information removed. Do not send complete logs, serial numbers, private paths, passwords or sensitive attachments. Remove personal information from screenshots. If further material is needed, we will explain the minimum necessary scope first. No fixed response time is promised.